Special Cables
Trailing cables Cables for renewable energy Single Conductor Airport 400Hz Truck cables more

CALETRUCK - H

Application

These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial

vehicles.Especially suitable for trailers and semi trailers manufactured for the transport of GGVS hazardous

substances.

Construction

Bare copper, fine wire in acc. with DIN VDE 0295 cl. 5 or IEC 60228 cl. 5

Conductor coding: up to 9 conductors by color, 10 conductors and above white with numbers (see below)

Inner jacket from special PVC

PUR outer jacket

Color black

Also available with PVC jacket

Temperature range:

-40°C to +85°C

test voltage:

2000 V min. 5 minutes

Minimum bending radius:

approx. 12 x cable Ø

Insulation resistance:

min. 20 MOhm x km

Capacitance

max. 50 pF/m for the data pair; max. 100 pF/m between data pair; conductors and the other conductors

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x1 6.0 19.0 56.0 17
2x0.75 + 2x1.5 7.0 43.2 91.0 18
2x1 6.0 19.0 56.0 17
2x1.5 6.6 28.8 67.0 16
2x1.5 6.6 28.8 67.0 16
2x4 + 3x1.5 + 2x1.5 12.0 148.8 230.0 12
2x6 + 3x1.5 + 2x1.5 12.0 187.2 320.0 10
2x6 + 3x1.5 12.0 158.6 270.0 10
3x1 6.3 28.8 66.0 17
3x1 6.3 28.8 66.0 17
4x1 6.8 38.5 80.0 17
4x1.5 7.5 57.6 105.0 16
5x1 7.5 48.1 98.0 17
5x1 + 1x0.25 9.0 72.0 132.0 17
5x1 + 1x2.5 9.0 72.0 132.0 17
5x1 + 1x2.5 9.0 72.0 132.0 17
5x1 + 1x2.5 9.0 72.0 132.0 17
6x1.5 + 1x2.5 10.3 110.4 187.0 16
7x0.75 7.9 50.4 100.0 18
7x1.5 8.9 100.8 165.0 16
8x1.5 + 1x2.5 11.7 139.2 238.0 16
10x1.5 + 3x2.5 + 2x1.5 14.4 244.8 393.0 16
10x1.5 + 3x2.5 14.4 214.0 366.0 16
10x1.5 + 3x2.5 14.4 214.0 366.0 16
18x1.5 17.0 259.2 520.0 16
25x1.5 19.9 360.0 730.0 16